PB dryers use heated blower purge air to remove moisture from the desiccant material and have therefore no purge loss during regeneration. The Zero Purge variants reduce life cycle costs even further by also eliminating purge loss during cooling. The cooling phase happens in a closed loop, hereby minimizing the performance impact at high ambient temperature and relative humidity.
Operating costs are reduced to the absolute minimum thanks to PDP control, regeneration & cooling temperature control and compressor synchronization; which are all integrated in the Purelogic™ controller. Zero Purge variants are equipped with a purge back-up mode which switches the dryer to purge cooling mode in case PDP could not be met at ambient conditions outside of limitations.
Technical specifications for PB 210 HE up to PB 635 HE (ZP) (standard version, PDP -40˚C) |
||||||
Specification |
Unit |
PB 210HE |
PB 320 HE |
PB 390 HE |
PB 530 HE |
PB 635 HE |
Cooling Mode |
- |
Purge |
Purge |
Purge |
Purge |
Purge |
Nominal volume flow at dryer inlet (1) |
l/s |
100 |
150 |
185 |
250 |
300 |
m3/hr |
360 |
540 |
666 |
900 |
1080 |
|
Purge air consumption average |
% |
2 |
2 |
2 |
2 |
2 |
Pressure drop over dryer |
barg |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
psig |
2.90 |
2.90 |
2.90 |
2.90 |
2.90 |
|
Inlet and outlet connections |
G/NPT |
1 ½”
|
1 ½”
|
1 ½”
|
2”
|
2”
|
DN, acc. to DIN2633 PN16 |
- | - | - | - | - | |
Included pre and after filters |
Fine filter |
TF 6 G HE |
TF 7 G HE |
TF 8 G HE |
TF 9 G HE |
TF 9 G HE |
Super fine filter |
TF 6 C HE |
TF 7 C HE |
TF 8 C HE |
TF 9 C HE |
TF 9 C HE |
|
Dust filter |
TF 6 S HE |
TF 7 S HE |
TF 8 S HE |
TF 9 S HE |
TF 9 S HE |
|
Height |
mm |
1720
67.7 |
1770
69.7 |
1770
69.7 |
1816
71.5 |
1853
73.0 |
inch |
||||||
Width |
mm |
770 |
870 |
870 |
955 |
1010 |
inch |
30.3 |
34.3 |
34.3 |
37.6 |
39.8 |
|
Length |
mm |
1250
49.2 |
1300
51.2 |
1300
51.2 |
1345
53.0 |
1425
56.1 |
inch |
||||||
Mass |
kg |
640 |
680 |
710 |
775 |
820 |
lbs |
1411 |
1499 |
1565 |
1709 |
1808 |
Technical specifications for PB 210 HE up to PB 635 HE (ZP) (standard version, PDP -40˚C) |
||||||
Specification |
Unit |
PB 210 HE ZP |
PB 320 HE ZP |
PB 390 HE ZP |
PB 530 HE ZP |
PB 635 HE ZP |
Cooling Mode |
- |
Zero Purge |
Zero Purge |
Zero Purge |
Zero Purge |
Zero Purge |
Nominal volume flow at dryer inlet (1) |
l/s |
100 |
150 |
185 |
250 |
300 |
m3/hr |
360 |
540 |
666 |
900 |
1080 |
|
Purge air consumption average |
% |
0 |
0 |
0 |
0 |
0 |
Pressure Drop Over Dryer |
barg |
0.2 |
0.2 |
0.2 |
0.2 |
0.2 |
psig |
2.90 |
2.90 |
2.90 |
2.90 |
2.90 |
|
Inlet and outlet connections |
G/NPT |
1 ½”
|
1 ½”
|
1 ½”
|
2”
|
2” |
DN, acc to DIN2633 PN16 |
- | - | - | - | - | |
Optional pre and after filter sizes (2) |
Fine filter |
TF 6 G HE | TF 7 G HE |
TF 8 G HE |
TF 9 G HE |
TF 9 G HE |
Super fine filter |
TF 6 C HE |
TF 7 C HE |
TF 8 C HE |
TF 9 C HE |
TF 9 C HE |
|
Dust filter |
TF 6 S HE |
TF 7 S HE |
TF 8 S HE |
TF 9 S HE |
TF 9 S HE |
|
Height |
mm |
1855
73.0 |
1891
74.4 |
1891
74.4 |
1969
77.5 |
2006
79.0 |
inch |
||||||
Width |
mm |
840 |
966 |
966 |
1098 |
1123 |
inch |
33.1 |
38.0 |
38.0 |
43.2 |
44.2 |
|
Length |
mm |
1174
46.2 |
1360
53.5 |
1360
53.5 |
1580
62.2 |
1507
59.3 |
inch |
||||||
Mass |
kg |
400 |
498 |
537 |
663 |
765 |
lbs |
882 |
1098 |
1184 |
1462 |
1687 |