FAQ

AC 650-2100 VSD Cycling Dryers

Reliable refrigeration dryers with variable speed technology, which match energy consumption to the actual compressed air demand

Contact your local expert

Premium energy efficiency

The Variable Speed Drive (VSD) matches the energy consumption to the actual air demand, hereby reducing energy costs up to 70%, compared to traditional dryers.

Stable pressure dew point

The variable speed drive reduces the speed of the refrigerant compressor, hereby ensuring a stable dew point at all times.

Purelogic Controller

The Purelogic ensures maximum reliability by monitoring the most important parameters of the dryer and offers impressive control and monitoring capabilities, like internet-based visualization.

Rotary compressors & R410A

The range is equipped with rotary compressors and R410A refrigerant. This combination is up to 30% more energy efficient; requires 19% less refrigerant charge and is 100% compliant to future European legislation

Superior performance & reliability

The refrigeration cycle is optimized in all conditions thanks to the use of automatic expansion valves and electronic hot gas bypass valves.

Availability of water-cooled condensers

The AC650-2100 VSD range is available with both air-cooled and water-cooled condensers.

Compressed air refrigerant dryer for superior performance and reliability

AC 650-2100 is Pneumatech’s premium refrigeration dryer range at higher flows: from 1120 up to 3636 m³/hr (657-2141 cfm).

As in the small AC range, operating costs are significantly reduced thanks to the energy saving and flow switch algorithms, the zero-loss drains, the low pressure drop over the heat exchangers and the combination of rotary compressors and R410A refrigerant. The refrigeration cycle is further optimized in all working conditions by making use of the automatic expansion valve & electronic hot gas bypass valve.

From AC 650 onwards, dedicated variable speed (VSD) variants have been added to the range. The VSD controller incorporated in these dryers matches the energy consumption to the actual compressed air demand. This reduces energy used by as much as 70%, compared to conventional dryers. It works by varying the speed of the compressor, hereby ensuring a stable dew point.

The PurelogicTM is installed as standard on all dryers: it ensures maximum reliability by monitoring the most important parameters of the dryer and offers impressive control and monitoring capabilities, like internet-based visualization. The entire range is available in both air-cooled and water-cooled versions.

Technical specifications AC 650 - 2100 fixed speed

 

Air Cooled

Water Cooled

Pneumatech Variant Specifications

 

Units

 

AC 650

 

AC850

 

AC 1050

 

AC 1250

 

AC 1600

 

AC 1800

 

AC 2100

 

AC 650

 

AC 850

 

AC 1050

 

AC 1250

 

AC 1600

 

AC1800

 

AC2100

 

Flow (1)

l/s

310

1116

410

1476

510

1836

610

2196

760

2736

870

3132

1010

3636

310

1116

410

1476

510

1836

610

2196

760

2736

870

3132

1010

3636

m3/hr

Power consumption

kW

2.80

3

4.5

4.8

5.3

6.6

7.4

2.00

2.4

4.1

3.1

3.6

4.5

5.1

hp

3.75

4.02

6.03

6.44

7.11

8.85

9.92

2.68

3.22

5.50

4.16

4.83

6.03

6.84

Pressure drop over dryer

mbar

230

3.3

210

3.0

200

2.9

170

2.5

170

2.5

140

2.0

170

2.5

230

3.3

210

3.0

200

2.9

170

2.5

170

2.5

140

2.0

170

2.5

psi

Refrigerant type

 

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

R410A

 

L (mm)

1263

1263

1525

1040

1245

1245

1580

1263

1263

1263

1245

1580

1245

1245

 

L (inch)

49.7

49.7

60.0

40.9

49.0

49.0

62.2

49.7

49.7

49.7

49.0

62.2

49.0

49.0

 

Dimensions

W (mm)

850

33.5

850

33.5

850

33.5

1060

41.7

1060

41.7

1060

41.7

1060

41.7

850

33.5

850

33.5

850

33.5

1060

41.7

1060

41.7

1060

41.7

1060

41.7

W (inch)

 

H (mm)

1190

1375

1580

1580

1580

1580

1580

1190

1375

1375

1580

1580

1580

1580

 

H (inch)

46.9

54.1

62.2

62.2

62.2

62.2

62.2

46.9

54.1

54.1

62.2

62.2

62.2

62.2

Inlet and Outlet

Connections

 

G3"

G3"

G3"

DN100

DN100

DN150

DN150

G3"

G3"

G3"

DN100

DN150

DN150

DN150

 

Weight

kg

200

441

245

540

310

683

320

705

380

838

400

882

460

1014

180

397

245

540

265

584

350

772

360

794

370

816

380

838

Technical specifications AC 650 - 2100 VSD

 

Air Cooled

Water Cooled

Pneumatech Variant Specifications

 

Units

AC 650 VSD

AC 850 VSD

AC 1050 VSD

AC 1600 VSD

AC 1800 VSD

AC 2100 VSD

AC 650 VSD

AC 850 VSD

AC 1050 VSD

AC 1600 VSD

AC 1800 VSD

AC 2100 VSD

 

Flow (1)

l/s

310

1116

410

1476

510

1836

760

2736

870

3132

1010

3636

310

1116

410

1476

510

1836

760

2736

870

3132

1010

3636

m3/hr

Power consumption

kW

2.28

3.02

3.38

5.3

5.8

6.6

1.48

2.2

2.78

3.3

4.2

5.6

hp

3.06

4.05

4.53

7.11

7.78

8.85

1.98

2.95

3.73

4.43

5.63

7.51

Pressure drop over dryer

mbar

230

3.3

210

3.0

200

2.9

170

2.5

140

2.0

170

2.5

230

3.3

210

3.0

200

2.9

90

1.3

120

1.7

170

2.5

psi

Refrigerant type

 

R410A

R410A

R410A

R410A

R410A

R410A

R410A

R410A

R410A

R410A

R410A

R410A

 

L (mm)

1263

1263

1263

1245

1245

1580

1263

1263

1263

1580

1580

1580

 

L (inch)

49.7

49.7

49.7

49.0

49.0

62.2

49.7

49.7

49.7

62.2

62.2

62.2

 

Dimensions

W (mm)

850

33.5

850

33.5

850

33.5

1060

41.7

1060

41.7

1060

41.7

850

33.5

850

33.5

850

33.5

1060

41.7

1060

41.7

1060

41.7

W (inch)

 

H (mm)

1190

1375

1375

1580

1580

1580

1190

1375

1375

1580

1580

1580

 

H (inch)

46.9

54.1

54.1

62.2

62.2

62.2

46.9

54.1

54.1

62.2

62.2

62.2

Inlet and Outlet

Connections

 

ISO7-R3*

ISO7-R3*

ISO7-R3*

DN100

DN150

DN150

ISO7-R3*

ISO7-R3*

ISO7-R3*

DN150

DN150

DN150

 

Weight

kg

218

481

245

540

265

584

380

838

400

882

460

1014

200

441

245

540

265

584

410

904

410

904

410

904

Refrigeration Dryers

Refrigeration dryers are the most commonly used dryers for removing moisture from compressed air. They therefore play an important role in shielding compressed air systems from corrosion and protecting your equipment and end products alike.