Reliable Wet Air Measurement
Accurate monitoring in demanding conditions
The Flow Check Universal W is designed to measure moist compressed air immediately downstream of the compressor, ensuring precise flow, temperature, and pressure readings even in high-humidity environments.
High-Temperature Resilience
Performance up to 180°C
Built to withstand extreme conditions, this flow sensor operates reliably at temperatures up to 180°C, making it ideal for hot, moisture-laden air systems where standard sensors may fail.
Fast and Flexible Integration
Quick response & easy installation
With an ultra-fast response time of 100 ms, it provides real-time data for efficient monitoring. Installation is quick and secure, even under pressure, via a 1/2” ball valve, ensuring seamless integration into compressed air systems.
General specifications
Technical data Flow Check Universal W |
|
---|---|
Measuring range |
up to 224 m/s / 600 m/s |
Measured medium |
Air, non-aggressive gases |
Accuracy |
± 1.5% of m.v. ± 0.3% of f.s.(20...224 m/s) |
Measuring principle |
Differential pressure |
Measuring span |
1:10 |
Response time |
t 99: < 1 sec. |
Temperature of the medium |
-30 °…+180 °C |
Operating pressure |
Max. 20 bar |
Ambient temperature |
-30 ° … +70 °C |
Screw-in thread |
G 1/2″, ISO 228 |
Power supply |
18 … 36 VDC, 5 W |
Signal outputs |
As standard: RS 485 (Modbus-RTU), 4…20 mA, pulse |
- Particularly suitable for extremely high flow rates
- Extremely fast response time: 100 ms
- Flow, total consumption, temperature and pressure
- Measurement at high temperatures, max. temperature 180 °C
- Measurement in various gases by selecting the gas type, on request
- Can be used in pipes from DN 20 to DN 500
- Installation via 1/2″ ball valve under pressure
- RS 485 interface (Modbus-RTU), 4...20 mA, pulse output as standard